{"title":"Mitsubishi Electric Heat Pumps","description":"\u003ch3 data-start=\"3422\" data-end=\"3463\"\u003e\u003cstrong data-start=\"3426\" data-end=\"3461\"\u003eMitsubishi Electric Spare Parts\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3465\" data-end=\"3781\"\u003eVarmetec offers a full range of Mitsubishi Electric heat pump spare parts to support ongoing maintenance, servicing, and repairs. As one of the UK’s leading suppliers, we provide genuine components for Mitsubishi Ecodan air source and ground source systems — trusted for their innovation and energy efficiency.\u003c\/p\u003e\n\u003cp data-start=\"3783\" data-end=\"3991\"\u003eOur extensive stock includes fans, sensors, compressors, expansion valves, pumps, and PCB control boards. Every part is genuine or manufacturer-approved to ensure full compatibility and lasting reliability.\u003c\/p\u003e\n\u003cp data-start=\"3993\" data-end=\"4217\"\u003eWe understand how important it is to source parts quickly. That’s why Varmetec offers expert support and fast delivery across the UK, helping engineers, installers, and homeowners keep their systems performing efficiently.\u003c\/p\u003e\n\u003cp data-start=\"4219\" data-end=\"4399\"\u003eMaintain the comfort, reliability, and energy efficiency of your Mitsubishi Electric heat pump with genuine spare parts from Varmetec — your dependable renewable heating partner.\u003c\/p\u003e","products":[{"product_id":"expansion-vessel-white","title":"18L - Hot Water Expansion Vessel","description":"\u003ch4 data-start=\"108\" data-end=\"170\"\u003e\u003cstrong data-start=\"112\" data-end=\"170\"\u003eHot Water Expansion Vessel – 18L (White, Wall-Mounted) - small demand\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"177\" data-end=\"192\" class=\"\"\u003e\u003cstrong data-start=\"177\" data-end=\"190\"\u003eFunction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"193\" data-end=\"467\"\u003e\n\u003cli data-start=\"193\" data-end=\"265\" class=\"\"\u003e\n\u003cp data-start=\"195\" data-end=\"265\" class=\"\"\u003e\u003cstrong data-start=\"195\" data-end=\"228\"\u003eWall-mounted expansion vessel\u003c\/strong\u003e designed for \u003cstrong data-start=\"242\" data-end=\"263\"\u003ehot water systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"266\" data-end=\"362\" class=\"\"\u003e\n\u003cp data-start=\"268\" data-end=\"362\" class=\"\"\u003eAbsorbs pressure fluctuations as water heats and expands, protecting pipework and components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"363\" data-end=\"467\" class=\"\"\u003e\n\u003cp data-start=\"365\" data-end=\"467\" class=\"\"\u003eHelps maintain stable pressure within the unvented system and prevents activation of safety components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"474\" data-end=\"495\" class=\"\"\u003e\u003cstrong data-start=\"474\" data-end=\"493\"\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"496\" data-end=\"646\"\u003e\n\u003cli data-start=\"496\" data-end=\"523\" class=\"\"\u003e\n\u003cp data-start=\"498\" data-end=\"523\" class=\"\"\u003e\u003cstrong data-start=\"498\" data-end=\"510\"\u003eCapacity\u003c\/strong\u003e: 18 Litres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"524\" data-end=\"544\" class=\"\"\u003e\n\u003cp data-start=\"526\" data-end=\"544\" class=\"\"\u003e\u003cstrong data-start=\"526\" data-end=\"535\"\u003eColour\u003c\/strong\u003e: White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"545\" data-end=\"575\" class=\"\"\u003e\n\u003cp data-start=\"547\" data-end=\"575\" class=\"\"\u003e\u003cstrong data-start=\"547\" data-end=\"559\"\u003eMounting\u003c\/strong\u003e: Wall-mounted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"576\" data-end=\"607\" class=\"\"\u003e\n\u003cp data-start=\"578\" data-end=\"607\" class=\"\"\u003e\u003cstrong data-start=\"578\" data-end=\"597\"\u003eConnection Size\u003c\/strong\u003e: ¾\" BSP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"608\" data-end=\"646\" class=\"\"\u003e\n\u003cp data-start=\"610\" data-end=\"646\" class=\"\"\u003e\u003cstrong data-start=\"610\" data-end=\"625\"\u003eSystem Type\u003c\/strong\u003e: Hot Water (Potable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"653\" data-end=\"681\" class=\"\"\u003e\u003cstrong data-start=\"653\" data-end=\"679\"\u003eCommon Fault Symptoms:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"682\" data-end=\"935\"\u003e\n\u003cli data-start=\"682\" data-end=\"736\" class=\"\"\u003e\n\u003cp data-start=\"684\" data-end=\"736\" class=\"\"\u003eVessel fails to \u003cstrong data-start=\"700\" data-end=\"717\"\u003ehold pressure\u003c\/strong\u003e (no air cushion)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"737\" data-end=\"856\" class=\"\"\u003e\n\u003cp data-start=\"739\" data-end=\"856\" class=\"\"\u003eCauses \u003cstrong data-start=\"746\" data-end=\"791\"\u003ecold water combination valve arrangements\u003c\/strong\u003e (e.g. \u003cstrong data-start=\"798\" data-end=\"817\"\u003ePart No. 524277\u003c\/strong\u003e) to be placed under excessive stress\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"857\" data-end=\"935\" class=\"\"\u003e\n\u003cp data-start=\"859\" data-end=\"935\" class=\"\"\u003eLeads to \u003cstrong data-start=\"868\" data-end=\"901\"\u003epressure relief valves (PRVs)\u003c\/strong\u003e failing or \u003cstrong data-start=\"913\" data-end=\"935\"\u003econstantly passing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"942\" data-end=\"960\" class=\"\"\u003e\u003cstrong data-start=\"942\" data-end=\"958\"\u003eApplication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"961\" data-end=\"1167\"\u003e\n\u003cli data-start=\"961\" data-end=\"1096\" class=\"\"\u003e\n\u003cp data-start=\"963\" data-end=\"1096\" class=\"\"\u003eReplacement is recommended during annual service or when system pressure issues, PRV weeping, or cold water valve wear are observed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1097\" data-end=\"1167\" class=\"\"\u003e\n\u003cp data-start=\"1099\" data-end=\"1167\" class=\"\"\u003eShould be pre-charged to match system pressure before installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Aquasystem","offers":[{"title":"Default Title","offer_id":45538152186160,"sku":"vw03","price":65.06,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0003_f64d09ae-afef-484b-93f2-c38cee9c199d.jpg?v=1717681332"},{"product_id":"mitsubishi-electric-temperature-controller","title":"Mitsubishi Electric heat pump Controller and module - PAC-IF031 B-E","description":"\u003cp class=\"\" data-end=\"183\" data-start=\"100\"\u003e\u003cstrong data-end=\"183\" data-start=\"100\"\u003eReconditioned Flow Temp Controller (PAC-IF031 B-E) - Including Wired Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"489\" data-start=\"185\"\u003eOptimize the performance of your \u003cstrong data-end=\"251\" data-start=\"218\"\u003eAir-to-Water heat pump system\u003c\/strong\u003e with the \u003cstrong data-end=\"315\" data-start=\"261\"\u003eReconditioned Flow Temp Controller (PAC-IF031 B-E)\u003c\/strong\u003e. This high-quality control module features a cased PCB and sensors, designed to regulate and monitor the temperature, ensuring your system operates efficiently and reliably.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"788\" data-start=\"491\"\u003eThe \u003cstrong data-end=\"512\" data-start=\"495\"\u003ePAC-IF031 B-E\u003c\/strong\u003e controller includes a \u003cstrong data-end=\"555\" data-start=\"535\"\u003ewired controller\u003c\/strong\u003e, offering intuitive operation and precise temperature management. Having been \u003cstrong data-end=\"647\" data-start=\"634\"\u003eused once\u003c\/strong\u003e, this reconditioned unit is still in excellent condition, providing cost-effective performance with the same reliability as a new component.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"807\" data-start=\"790\"\u003e\u003cstrong data-end=\"807\" data-start=\"790\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1206\" data-start=\"808\"\u003e\n\u003cli class=\"\" data-end=\"886\" data-start=\"808\"\u003e\n\u003cp class=\"\" data-end=\"886\" data-start=\"810\"\u003e\u003cstrong data-end=\"827\" data-start=\"810\"\u003eReconditioned\u003c\/strong\u003e for cost-effective performance without sacrificing quality\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"959\" data-start=\"887\"\u003e\n\u003cp class=\"\" data-end=\"959\" data-start=\"889\"\u003eIncludes \u003cstrong data-end=\"911\" data-start=\"898\"\u003ecased PCB\u003c\/strong\u003e and \u003cstrong data-end=\"927\" data-start=\"916\"\u003esensors\u003c\/strong\u003e for precise temperature control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1028\" data-start=\"960\"\u003e\n\u003cp class=\"\" data-end=\"1028\" data-start=\"962\"\u003e\u003cstrong data-end=\"982\" data-start=\"962\"\u003eWired controller\u003c\/strong\u003e included for easy system management and setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1121\" data-start=\"1029\"\u003e\n\u003cp class=\"\" data-end=\"1121\" data-start=\"1031\"\u003eDesigned specifically to control \u003cstrong data-end=\"1091\" data-start=\"1064\"\u003eAir-to-Water heat pumps\u003c\/strong\u003e, optimizing system efficiency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1206\" data-start=\"1122\"\u003e\n\u003cp class=\"\" data-end=\"1206\" data-start=\"1124\"\u003e\u003cstrong data-end=\"1137\" data-start=\"1124\"\u003eUsed once\u003c\/strong\u003e, thoroughly tested to ensure excellent functionality and reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"\" data-end=\"1408\" data-start=\"1208\"\u003eUpgrade your \u003cstrong data-end=\"1254\" data-start=\"1221\"\u003eAir-to-Water heat pump system\u003c\/strong\u003e with the \u003cstrong data-end=\"1318\" data-start=\"1264\"\u003eReconditioned Flow Temp Controller (PAC-IF031 B-E)\u003c\/strong\u003e, offering dependable control and enhanced performance for your heating and cooling needs.\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":49184813678896,"sku":"vrc07","price":450.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0023.jpg?v=1729701931"},{"product_id":"rubber-compressor-feet-dampers","title":"Rubber Compressor Feet\/Dampers - Universal Compatibility","description":"\u003cp data-start=\"130\" data-end=\"232\" class=\"\"\u003e\u003cstrong data-start=\"130\" data-end=\"232\"\u003eNibe \u003cspan\u003e425843\u003c\/span\u003e \u0026amp; LG MCQ68888201 Rubber Feet\/Dampers (1 Pack = 3) - Compatible with Nibe, LG, and More\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"234\" data-end=\"627\" class=\"\"\u003eReplace worn-out or damaged rubber feet with this \u003cstrong data-start=\"284\" data-end=\"332\"\u003ehigh-quality 1-Pack of 3 Rubber Feet\/Dampers\u003c\/strong\u003e, designed for a wide range of air source heat pump systems. Perfectly compatible with \u003cstrong data-start=\"419\" data-end=\"445\"\u003eNibe F2040 12kW \u0026amp; 16kW\u003c\/strong\u003e units, as well as most \u003cstrong data-start=\"469\" data-end=\"514\"\u003eLG, Samsung, Hitachi, and Mitsubishi ASHP\u003c\/strong\u003e systems, this pack ensures smooth operation and minimizes vibrations to keep your heat pump running efficiently.\u003c\/p\u003e\n\u003cp data-start=\"629\" data-end=\"869\" class=\"\"\u003eThese rubber feet help to reduce noise, vibration, and movement, ensuring your heat pump remains stable and operates with minimal disruption. Crafted from durable materials, these feet are designed to last and provide long-term reliability.\u003c\/p\u003e\n\u003cp data-start=\"871\" data-end=\"888\" class=\"\"\u003e\u003cstrong data-start=\"871\" data-end=\"888\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"889\" data-end=\"1293\"\u003e\n\u003cli data-start=\"889\" data-end=\"963\" class=\"\"\u003e\n\u003cp data-start=\"891\" data-end=\"963\" class=\"\"\u003e\u003cstrong data-start=\"891\" data-end=\"925\"\u003e1 Pack = 3 Rubber Feet\/Dampers\u003c\/strong\u003e for easy installation and replacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"964\" data-end=\"1072\" class=\"\"\u003e\n\u003cp data-start=\"966\" data-end=\"1072\" class=\"\"\u003eCompatible with \u003cstrong data-start=\"982\" data-end=\"1008\"\u003eNibe F2040 12kW \u0026amp; 16kW\u003c\/strong\u003e, as well as \u003cstrong data-start=\"1021\" data-end=\"1066\"\u003eLG, Samsung, Hitachi, and Mitsubishi ASHP\u003c\/strong\u003e units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1073\" data-end=\"1155\" class=\"\"\u003e\n\u003cp data-start=\"1075\" data-end=\"1155\" class=\"\"\u003eEffectively reduces vibration, noise, and movement for smoother system operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1156\" data-end=\"1223\" class=\"\"\u003e\n\u003cp data-start=\"1158\" data-end=\"1223\" class=\"\"\u003eMade from durable, high-quality materials for lasting performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1224\" data-end=\"1293\" class=\"\"\u003e\n\u003cp data-start=\"1226\" data-end=\"1293\" class=\"\"\u003eIdeal for maintaining the integrity and stability of your heat pump\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1295\" data-end=\"1495\" class=\"\"\u003eWhether you’re maintaining your \u003cstrong data-start=\"1327\" data-end=\"1335\"\u003eNibe\u003c\/strong\u003e unit or another brand of air source heat pump, this rubber feet\/damper pack offers a reliable and cost-effective solution to improve performance and longevity.\u003c\/p\u003e","brand":"Nibe","offers":[{"title":"Default Title","offer_id":54975443796344,"sku":"vn110","price":34.61,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0006_ba573ff0-cbf5-47c9-bbce-d9c6e0afefc6.jpg?v=1741884941"},{"product_id":"mitsubishi-control-pcb-t7wgv0315","title":"Mitsubishi Control PCB - T7W GV0 315","description":"\u003cp\u003e\u003c!--StartFragment --\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eMitsubishi Electric T7W GV0 315 Control PCB\u003c\/strong\u003e is a genuine OEM circuit board designed for use in specific outdoor units. It plays a critical role in managing the system’s operations, including temperature regulation, compressor control, and communication with indoor units.\u003c\/p\u003e\n\u003cp\u003eHere are some key details:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: It fits models like PUHZ-W50VHA2, PUHZ-W50VHA2-BS, PUHZ-W50VHA2R1-BS, and RPUHZ-W50VHA21.SH.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 289266 (also listed under SKU M289266-01).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction\u003c\/strong\u003e: As the main control board, it processes signals from sensors and user inputs, ensuring the system runs efficiently and safely.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c!--EndFragment --\u003e\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55173338890616,"sku":"vme01","price":349.64,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0022_52aa8496-e3b3-44c4-ae2b-7eb41466dff0.jpg?v=1750429319"},{"product_id":"mitsubishi-fan-blade-r01e06115","title":"Mitsubishi Fan Blade R01E06115","description":"\u003cp\u003e\u003c!--StartFragment --\u003e\u003c\/p\u003e\n\u003cp\u003eThe Mitsubishi Electric part \u003cstrong\u003e209155 - R01E06115\u003c\/strong\u003e is a \u003cstrong\u003epropeller fan\u003c\/strong\u003e designed for the \u003cstrong\u003ePUHZ-P-YHA\u003c\/strong\u003e series of outdoor air conditioning or heat pump units. It's a genuine replacement component used in HVAC systems to ensure proper airflow and cooling efficiency.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility\u003c\/strong\u003e: It fits models like, \u003c!--StartFragment --\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003ePUHZ-P250YHA, \u003c\/strong\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003ePUHZ-RP140YHA2, \u003c\/strong\u003e\u003c!--EndFragment --\u003e\u003cstrong\u003ePUHZ-RP14, \u003c\/strong\u003e\u003cstrong\u003ePUY-A36NHA6, \u003c\/strong\u003e\u003cstrong\u003eMPUZ-WRP160HA3-A, \u003c\/strong\u003e\u003cstrong\u003eMPUZ-WRP140HA3-A\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003c!--StartFragment --\u003e\u003c\/strong\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eType: \u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003ePropeller fan blade, designed specifically for Mitsubishi Electric HVAC systems. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c!--EndFragment --\u003e\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55173408817528,"sku":"vme02","price":65.45,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0019_88f3e397-4932-465f-acbf-b1e425cbf7d4.jpg?v=1750432855"},{"product_id":"mitsubishi-fan-motor-r01e72221","title":"Mitsubishi Fan Motor - R01E72221","description":"\u003cp\u003eThe Mitsubishi Electric part \u003cstrong\u003e289757 - R01E72221\u003c\/strong\u003e is a \u003c!--StartFragment --\u003e\u003cem\u003e\u003c\/em\u003eoutdoor fan motor commonly used in Mitsubishi Electric mini-split HVAC systems.\u003c\/p\u003e\n\u003cp\u003e\u003c!--StartFragment --\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplaces or Cross-References\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePanasonic EHDS81A86MS3\u003c\/li\u003e\n\u003cli\u003eRG61N769H07\u003c\/li\u003e\n\u003cli\u003e859813CA\u003c\/li\u003e\n\u003cli\u003e1629CG\u003c\/li\u003e\n\u003cli\u003eX06RS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Mitsubishi Models\u003c\/strong\u003e (partial list):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePUZ-A24NHA6\u003c\/li\u003e\n\u003cli\u003ePUY-A36NHA6\u003c\/li\u003e\n\u003cli\u003ePUHZ-P250YHA\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003ePUHZ-RP140YHA2\u003c\/span\u003e\u003c\/li\u003e\n\u003c!--EndFragment --\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c!--EndFragment --\u003e\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55193804996984,"sku":"vme03","price":225.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0023_8a6b79ec-c82b-4173-b697-2f74f78f95df.jpg?v=1751894579"},{"product_id":"mitsubishi-controller-board-t7w-gjo-315","title":"Mitsubishi Controller Board - T7W GJO 315","description":"\u003cp\u003e\u003cstrong\u003eMitsubishi Electric T7W GJO 315 MAIN CONTROLLER BOARD\u003c\/strong\u003e is a genuine OEM circuit board designed for use in specific HVAC systems. It plays a critical role in managing the system’s operations, including temperature regulation, compressor control, and communication with indoor or outdoor units.\u003c\/p\u003e\n\u003cp\u003eHere are some key details:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility: \u003c\/strong\u003eIt fits models like PUHZ-HW140VHA2R3 \u0026amp;  PUHZ-HW140VHA2R4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction\u003c\/strong\u003e: As the main control board, it processes signals from sensors and user inputs, ensuring the system runs efficiently and safely.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55349569782136,"sku":"vme04","price":369.96,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0088.jpg?v=1762286577"},{"product_id":"mitsubishi-grille-r01e33691","title":"Mitsubishi Grille R01E33691","description":"\u003cp\u003eThe \u003cstrong\u003eR01E33691 is a genuine Mitsubishi Electric\u003c\/strong\u003e outdoor fan grille, used as a replacement part for PUHZ-series heat pump units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Details\u003c\/strong\u003e\u003cbr\u003e•     Part number: R01E33691\u003cbr\u003e•     Type: Outdoor fan grille \/ protective louvre\u003cbr\u003e•     Manufacturer: Mitsubishi Electric\u003cbr\u003e•     Function: Protects the outdoor fan assembly while allowing airflow.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Models\u003c\/strong\u003e\u003cbr\u003eThis grille is compatible with several Mitsubishi Electric PUHZ units, including:\u003cbr\u003e•     PUHZ-HW112YHA \/ HW112YHA-BS \/ HW112YHA2 \/ HW112YHA2-BS\u003cbr\u003e•     PUHZ-HW140VHA \/ HW140VHA-BS \/ HW140VHA2 \/ HW140VHA2-BS \/   HW140VHA2R1-BS\u003cbr\u003e•     PUHZ-HW140YHA \/ HW140YHA-BS \/ HW140YHA2 \/ HW140YHA2-BS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Use\u003c\/strong\u003e\u003cbr\u003e•     Installed on the outdoor unit casing of PUHZ heat pumps.\u003cbr\u003e•     Ensures safe operation by shielding the fan from debris, accidental contact, and weather exposure.\u003cbr\u003e•     Replacement is usually required if the grille is damaged, bent, or corroded.\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55369947087224,"sku":"vme05","price":89.99,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0108_b928e0bd-266a-4dc3-9354-d031f55d053f.jpg?v=1764011947"},{"product_id":"mitsubishi-wireless-control-par-wt60r-e","title":"Mitsubishi Wireless Control - PAR-WT60R-E","description":"\u003cp\u003eThe \u003cstrong\u003eMitsubishi Electric PAR-WT60R-E\u003c\/strong\u003e is a wireless remote controller designed for Ecodan air-to-water heat pump systems. It works with the PAR-WR61R-E receiver to provide flexible, intuitive control of your heating system from anywhere in the home.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003cbr\u003e•     Wireless connectivity – control your Ecodan heat pump without being tethered to a wall unit\u003cbr\u003e•     Flat panel design – sleek, modern look that blends into interiors\u003cbr\u003e•     Touch buttons with user-friendly icons – simple and intuitive operation\u003cbr\u003e•     Backlit display screen – easy to read in low-light conditions\u003cbr\u003e•     Auto adaptive control logic – optimizes system efficiency by learning usage patterns\u003cbr\u003e•     Multiple controllers supported – up to 6–8 transmitters can be paired with one receiver, allowing zone control\u003cbr\u003e•     Comfort modes – includes water boost mode and holiday mode for tailored heating\u003cbr\u003e•     Temperature display – shows readings in 0.5°C increments for precision\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Setup\u003c\/strong\u003e\u003cbr\u003e•     Transmitter: PAR-WT60R-E (wireless controller)\u003cbr\u003e•     Receiver: PAR-WR61R-E (connects directly to the Ecodan heat pump)\u003cbr\u003e•     Compatibility: Works with Mitsubishi Electric Ecodan systems fitted with the FTC5 controller\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55374524416376,"sku":"vme06","price":110.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0125.jpg?v=1764275136"},{"product_id":"mitsubishi-control-board-pac-if010-5","title":"Mitsubishi Control Board - PAC-IF010-5","description":"\u003cp\u003eThe \u003cstrong\u003eMitsubishi PAC-IF010-5 PCB Control Board\u003c\/strong\u003e is a specialized interface board used in Mitsubishi Electric HVAC systems, particularly for connecting and controlling third-party evaporators with Mitsubishi outdoor units. It’s part of the PAC-IF series of control boards, designed to expand compatibility and integration options.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Details \u003c\/strong\u003e\u003cbr\u003e•     \u003cstrong\u003eFunctionality:\u003c\/strong\u003e The PAC-IF010 series boards allow third-party evaporators to be connected and operated with Mitsubishi Electric outdoor units, ensuring seamless integration between non-Mitsubishi indoor equipment and Mitsubishi systems.\u003cbr\u003e•     \u003cstrong\u003eModel Variants:\u003c\/strong\u003e While \u003cstrong\u003ePAC-IF010-E\u003c\/strong\u003e is widely listed, the \u003cstrong\u003ePAC-IF010-5 \u003c\/strong\u003eis a related variant. Both serve as interface\/control boards for HVAC applications.\u003cbr\u003e•     \u003cstrong\u003eApplications:\u003c\/strong\u003e Commonly used in commercial HVAC installations where Mitsubishi outdoor units need to be paired with non-standard or custom indoor units.\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55379569639800,"sku":"vme07","price":169.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0146_c38e40b5-fb90-4426-a0b7-08512d707851.jpg?v=1764793885"},{"product_id":"mitsubishi-compressor-t97426607","title":"Mitsubishi Compressor - T97426607","description":"\u003cp\u003eMitsubishi Electric SNB130FGCMC compressor. This is a hermetic rotary compressor manufactured by Mitsubishi Electric, typically used in heat pumps, air conditioning and refrigeration systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Overview\u003cbr\u003e\u003c\/strong\u003e•     Model: SNB130FGCMC\u003cbr\u003e•     Part Number: T97436607\u003cbr\u003e•     Type: Hermetic rotary compressor\u003cbr\u003e•     Application: Residential and light commercial HVAC systems (split-type air conditioners, heat pumps, and refrigeration units)\u003cbr\u003e•     Refrigerant: Designed for R410A \u003cbr\u003e•     Cooling Capacity: Around 12,000–13,000 BTU\/h depending on system design\u003cbr\u003e•     Motor Type: Single-phase induction motor\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Units\u003c\/strong\u003e\u003cbr\u003e•     \u003cstrong\u003ePUHZ-W-VHA-BS\u003c\/strong\u003e (Mitsubishi Electric outdoor heat pump unit)\u003cbr\u003e•     Other Mitsubishi precision air conditioning and CRAC (Computer Room Air Conditioning) cabinets that use R410A rotary compressors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003cbr\u003e•     Compact Design: Rotary compressors are smaller and lighter compared to reciprocating types.\u003cbr\u003e•     Low Noise \u0026amp; Vibration: Mitsubishi’s engineering focuses on quiet operation for residential comfort.\u003cbr\u003e•     Durability: Uses advanced heat caulking and precision machining for long service life.\u003cbr\u003e•     Energy Efficiency: Optimized for inverter-driven systems, reducing power consumption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Notes\u003c\/strong\u003e\u003cbr\u003e•     Must be installed by a licensed HVAC technician.\u003cbr\u003e•     Ensure refrigerant compatibility (R410A).\u003cbr\u003e•     OEM replacement recommended to maintain system efficiency and warranty.\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55384629870968,"sku":"vme08","price":998.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0171.jpg?v=1765310222"},{"product_id":"mitsubishi-electric-heat-pump-module-pac-if013b-e","title":"Mitsubishi Electric heat pump module - PAC-IF013B-E","description":"\u003cp\u003e\u003cstrong\u003eMitsubishi Electric PAC‑IF013B‑E \u003c\/strong\u003eAir Handling Unit (AHU) Controller for Mr Slim Systems\u003cbr\u003eThe PAC‑IF013B‑E is Mitsubishi Electric’s dedicated Air Handling Unit Controller, designed to let a third‑party AHU use Mr Slim outdoor units as its heating and cooling source. It works with both R32 and R410A systems.\u003cbr\u003eAccording to Mitsubishi Electric’s official product page, the module can interface up to six Mr Slim outdoor units with a single AHU, providing a wide range of capacity options.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003cbr\u003e•     Interfaces Mr Slim outdoor units to AHUs — simplifies system design and installation\u003cbr\u003e•     Supports up to 6 outdoor units on one AHU for scalable capacity\u003cbr\u003e•     11‑step capacity control for smooth modulation and comfort\u003cbr\u003e•     Built‑in anti‑cycling protection to extend equipment life\u003cbr\u003e•     BEMS integration for external monitoring and control\u003cbr\u003e•     SD card ( not included )\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible\u003c\/strong\u003e outdoor units\u003cspan\u003e: PUZ-ZM 35VKA PUZ-ZM 50VKA PUZ-ZM 60VKA PUZ-ZM 71VKA PUZ-ZM 100VKA\/YKA PUZ-ZM 125VKA\/YKA PUZ-ZM 140VKA\/YKA PUZ-ZM 200YKA PUZ-ZM 250YKA PUZ-M 200YKA PUZ-M 250YKA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eInstallation Notes\u003cbr\u003eThe installation manual highlights that the PAC‑IF013B‑E is indoor‑only, not waterproof, and must be mounted where it’s protected from heat, humidity, oil, and steam.\u003cbr\u003eIt also includes thermistors and wiring accessories depending on the version.\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55406384480632,"sku":"vme09","price":399.89,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0169_b299f2d5-7d6b-44cc-ac17-cad8f1cfeb30.jpg?v=1767383589"},{"product_id":"mitsubishi-thermister-231270","title":"Mitsubishi Thermister - 231270","description":"\u003cp\u003e\u003cstrong\u003ePart number 231270 \/ S70E47202\u003c\/strong\u003e Mitsubishi Electric thermistor used on heat pumps, specifically a “Thermistor (Comp. Shell)” or TH3 defrost sensor. It is a genuine Mitsubishi component used in outdoor units to monitor coil temperature during defrost cycles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003cbr\u003e•     Official Mitsubishi Electric part numbers:\u003cbr\u003e•     S70E47202\u003cbr\u003e•     231270\u003cbr\u003e•     Function: Defrost\/coil temperature sensor (TH3) for outdoor heat pump units.\u003cbr\u003e•     Typical use: Ensures correct defrost operation by monitoring compressor shell or coil temperature.\u003cbr\u003e•     Cable length: ~1 metre (per product listings).\u003cbr\u003e•     Manufacturer model reference: PAC‑TH011‑E.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003cbr\u003eThe part is used across multiple Mitsubishi Ecodan and PUHZ outdoor units. Exact compatibility depends on model, but listings show it used in:\u003cbr\u003e•     \u003cstrong\u003ePUHZ‑W112VAA\u003c\/strong\u003e.UK and similar Ecodan heat pumps\u003cbr\u003e•     Other Mitsubishi TH3 defrost sensor applications (coil\/compressor shell)\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55423695356280,"sku":"vme10","price":52.79,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/231270-S70E47202-THERMISTOR-COMP-SHELL-Czujnik-defrostu-Mitsubishi-TH3.jpg?v=1768851063"},{"product_id":"mitsubishi-electric-controller-assy-492624","title":"Mitsubishi Electric Controller Assy - 492624","description":"\u003cp\u003eMitsubishi part S70C25200 (service ref. 492624) is a genuine OEM REMOCON Controller Assembly used on Mitsubishi Ecodan and some air‑conditioning interface units. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003cbr\u003e•     Part number: S70C25200\u003cbr\u003e•     Service reference: 492624\u003cbr\u003e•     Name: REMOCON Controller Assembly\u003cbr\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Hard‑wired controller for Mitsubishi Electric heat pumps \/ Ecodan systems\u003cbr\u003e•     Display: Full‑dot backlit LCD, large characters, adjustable contrast\u003cbr\u003e•     Use case: Standard wired controller for system operation and configuration\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003cbr\u003eThis REMOCON assembly is used with:\u003cbr\u003e•     Mitsubishi Ecodan wired controllers, including \u003cstrong\u003ePAC‑IF072B‑E\u003c\/strong\u003e \u003cbr\u003e•     Various Mitsubishi Electric air‑conditioning and ATW (air‑to‑water) interface units\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55423717409144,"sku":"vme11","price":291.74,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0184_82cc5af3-128e-4fd2-9060-f557db5e3987.jpg?v=1768855737"},{"product_id":"mitsubishi-electric-power-board-s700b2313","title":"Mitsubishi Electric Power Board - S700B2313","description":"\u003cp\u003eThe \u003cstrong\u003eMitsubishi power board S700B2313\u003c\/strong\u003e (part code 206599) is confirmed to be compatible with several specific outdoor heat‑pump units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Mitsubishi units\u003c\/strong\u003e\u003cbr\u003e•     PUHZ‑HW100YHA2.UK — listed as the matching power board for this outdoor unit.\u003cbr\u003e•     PUHZ‑P100VHA2 and PUHZ‑P100VHA3 — as compatible with the S700B2313 power board.\u003cbr\u003eThese are all Mitsubishi Electric PUHZ‑series outdoor units, typically used in Ecodan heat‑pump systems.\u003c\/p\u003e\n\u003cp\u003eMitsubishi PCBs are tightly matched to:\u003cbr\u003e•     The inverter design\u003cbr\u003e•     Compressor control logic\u003cbr\u003e•     Power-handling specifications\u003cbr\u003e•     Firmware and connector layout\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55484980429176,"sku":"vme12","price":621.47,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0212.jpg?v=1772483002"},{"product_id":"mitsubishi-electric-controller-board-s70b29315","title":"Mitsubishi Electric Controller Board - S70B29315","description":"\u003cp\u003eThe part number S70B29315 ( or S70B29315# or part code 739642) refers to a \u003cstrong\u003eMitsubishi Electric outdoor unit control PCB\u003c\/strong\u003e. Main control board for certain Mitsubishi air‑conditioning or heat‑pump outdoor units.\u003c\/p\u003e\n\u003cp\u003eWhat the part is\u003cbr\u003eThis board is described as a “Mitsubishi Electric Air Con Outdoor PCB – Control Board”, used in specific outdoor condenser units. It sits in the main control box and manages inverter logic, compressor control, and system communication.\u003c\/p\u003e\n\u003cp\u003eMitsubishi PCB codes beginning with S70B… or S70E… are typically:\u003cbr\u003e•     Outdoor unit control boards\u003cbr\u003e•    \u003cstrong\u003e Model‑specific\u003c\/strong\u003e\u003cbr\u003e•     Used in PUHZ, PUZ, or MUZ series depending on the exact suffix\u003cbr\u003eThe 739642 number is likely a supplier or SAP reference, not the Mitsubishi engineering code.\u003c\/p\u003e\n\u003cp\u003eCompatibility considerations\u003cbr\u003eBecause Mitsubishi boards are tightly matched to:\u003cbr\u003e•     Firmware\u003cbr\u003e•     Connector layout\u003cbr\u003e•     Compressor\/inverter type\u003cbr\u003e•     Outdoor unit series\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55484994191736,"sku":"vme13","price":341.62,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0216.jpg?v=1772484467"},{"product_id":"mitsubishi-electric-fan-motor-s70e15763","title":"Mitsubishi Electric Fan Motor -S70E15763","description":"\u003cp\u003e\u003cstrong\u003eMitsubishi Electric Fan Motor – S70E15763 \u003c\/strong\u003e(part code 290338) used in several Mitsubishi Ecodan and PUHZ-series heat pump units.\u003c\/p\u003e\n\u003cp\u003eThe S70E15763 fan motor designed for outdoor heat pump units. It drives the condenser fan, which is essential for heat exchange and overall system efficiency. Using the correct OEM motor helps maintain performance and avoid vibration or noise issues.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Units\u003c\/strong\u003e\u003cbr\u003eThis motor is compatible with many Ecodan and PUHZ models, including:\u003cbr\u003e•     PUHZ‑SW75VHAR4\/5 (various UK\/BS variants)\u003cbr\u003e•     PUHZ‑SW100VHAR4\/5\u003cbr\u003e•     PUHZ‑SW120VHAR4\/5\u003cbr\u003e•     PUHZ‑W85VHA2R4\/R5\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThings to check before ordering\u003cbr\u003e•     Confirm the full model number of your heat pump outdoor unit.\u003cbr\u003e•     Check whether your existing motor has the same reference code (S70E15763) on its label.\u003cbr\u003e\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55485008937336,"sku":"vme14","price":286.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0220.jpg?v=1772486675"},{"product_id":"sika-flow-switch-vvxc9s00umitsu10","title":"Sika Flow Switch - VVXC9S00UMITSU10","description":"\u003cp class=\"\" data-end=\"196\" data-start=\"106\"\u003e\u003cstrong data-end=\"196\" data-start=\"106\"\u003eVVXC9S00UMITSU10 Flow Sensor with Cable - Compatible with Most Heat Pump Water Systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"531\" data-start=\"198\"\u003eEnsure accurate water flow monitoring and optimal performance with the \u003cstrong\u003eVVXC9S00UMITSU10\u003c\/strong\u003e\u003cstrong data-end=\"312\" data-start=\"269\"\u003e Flow Sensor with Cable\u003c\/strong\u003e. This high-quality flow sensor is designed to provide efficient operation and prevent potential issues caused by improper flow rates.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"766\" data-start=\"533\"\u003eCompatible with most \u003cstrong data-end=\"581\" data-start=\"554\"\u003eheat pump water systems\u003c\/strong\u003e, this flow sensor is easy to install and ensures accurate measurements for seamless operation, making it an essential component for any system that requires precise water flow control.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"785\" data-start=\"768\"\u003e\u003cstrong data-end=\"785\" data-start=\"768\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1143\" data-start=\"786\"\u003e\n\u003cli class=\"\" data-end=\"870\" data-start=\"786\"\u003e\n\u003cp class=\"\" data-end=\"870\" data-start=\"788\"\u003e\u003cstrong data-end=\"814\" data-start=\"788\"\u003eFlow Sensor with Cable\u003c\/strong\u003e for accurate water flow monitoring in heat pump systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"950\" data-start=\"871\"\u003e\n\u003cp class=\"\" data-end=\"950\" data-start=\"873\"\u003eCompatible with \u003cstrong data-end=\"921\" data-start=\"889\"\u003emost heat pump water systems\u003c\/strong\u003e, providing broad versatility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1030\" data-start=\"951\"\u003e\n\u003cp class=\"\" data-end=\"1030\" data-start=\"953\"\u003eEnsures \u003cstrong data-end=\"991\" data-start=\"961\"\u003eoptimal system performance\u003c\/strong\u003e by maintaining proper water flow rates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1086\" data-start=\"1031\"\u003e\n\u003cp class=\"\" data-end=\"1086\" data-start=\"1033\"\u003e\u003cstrong data-end=\"1057\" data-start=\"1033\"\u003eDurable construction\u003c\/strong\u003e for long-lasting reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"\" data-end=\"1143\" data-start=\"1087\"\u003e\n\u003cp class=\"\" data-end=\"1143\" data-start=\"1089\"\u003e\u003cstrong data-end=\"1110\" data-start=\"1089\"\u003eEasy installation\u003c\/strong\u003e for a quick setup or replacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"\" data-end=\"1323\" data-start=\"1145\"\u003eEnhance the performance and reliability of your heat pump system with the \u003cstrong\u003eVVXC9S00UMITSU10\u003c\/strong\u003e\u003cstrong data-end=\"1262\" data-start=\"1219\"\u003e Flow Sensor with Cable\u003c\/strong\u003e, providing precise flow measurement for efficient operation.\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55495497122168,"sku":"vw55","price":194.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0220_694c96bf-f5c9-4505-8569-fe41f860f01a.jpg?v=1773089706"},{"product_id":"mitsubishi-control-board-r01sf9350","title":"Mitsubishi Control Board - R01SF9350","description":"\u003cp\u003e\u003cstrong\u003eMitsubishi Electric R01SF9350 MAIN CONTROLLER BOARD ( 735327 )\u003c\/strong\u003e is a genuine OEM circuit board designed for use in specific HVAC systems. It plays a critical role in managing the system’s operations, including temperature regulation, compressor control, and communication with indoor or outdoor units.\u003c\/p\u003e\n\u003cp\u003eHere are some key details:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility: \u003c\/strong\u003eIt fits models like \u003cstrong\u003ePUHZ-HW140VHA - HA2, HA-BS, HA2-BS \u0026amp; R1-BS\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction\u003c\/strong\u003e: As the main control board, it processes signals from sensors and user inputs, ensuring the system runs efficiently and safely.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55589860344184,"sku":"vme15","price":347.89,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0224_6afb6534-ff48-4613-a4d7-9b1adba39ae3.jpg?v=1784629682"},{"product_id":"heatmiser-ds1-manual-thermostat-v2","title":"Heatmiser DS1 Manual Thermostat V2","description":"\u003cdiv class=\"container\"\u003e\n\u003cdiv class=\"markdown markdown-main-panel enable-luminous-fast-follows enable-updated-hr-color stronger tutor-markdown-rendering\" id=\"model-response-message-contentr_81c7fb30c003c340\" aria-busy=\"false\" aria-live=\"off\" dir=\"ltr\"\u003e\n\u003cp data-path-to-node=\"0\" id=\"p-rc_185e5db4a2452d5b-92\"\u003e\u003cspan class=\"citation-180\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003e\u003cspan class=\"citation-180\"\u003eHeatmiser DS1 V2\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-180 citation-end-180\"\u003e is a 230V mains-powered, surface-mounted electronic dial thermostat designed for conventional, combi-boiler systems \u0026amp; Heat Pump systems. IM\u003c\/span\u003e\u003cspan class=\"source-title\"\u003eI Heatmiser.\u003c\/span\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eInstallation \u0026amp; Mounting\u003c\/h3\u003e\n\u003cblockquote data-path-to-node=\"4\"\u003e\n\u003cp data-path-to-node=\"4,0\" id=\"p-rc_185e5db4a2452d5b-93\"\u003e\u003cspan class=\"citation-179\"\u003e⚠️ \u003c\/span\u003e\u003cb data-path-to-node=\"4,0\" data-index-in-node=\"3\"\u003e\u003cspan class=\"citation-179\"\u003eSafety Warning:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-179 citation-end-179\"\u003e Always turn off the mains power to your heating system before removing or wiring the thermostat to prevent electric shock.\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/blockquote\u003e\n\u003col start=\"1\" data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\" id=\"p-rc_185e5db4a2452d5b-94\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSeparate the unit:\u003c\/b\u003e \u003cspan class=\"citation-178 citation-end-178\"\u003eLoosen the securing screws on the bottom face of the thermostat to pull the front cover away from the backplate.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\" id=\"p-rc_185e5db4a2452d5b-95\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eMount the backbox:\u003c\/b\u003e \u003cspan class=\"citation-177 citation-end-177\"\u003eUse the backplate as a template to mark and drill your wall holes, then secure it in place.\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eWire and reassemble:\u003c\/b\u003e Complete the wiring connections, snap the front cover back onto the backbox, and tighten the bottom securing screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-path-to-node=\"7\"\u003e2. Wiring Connections\u003c\/h3\u003e\n\u003cp data-path-to-node=\"8\" id=\"p-rc_185e5db4a2452d5b-96\"\u003e\u003cspan class=\"citation-176 citation-end-176\"\u003eThe DS1 V2 utilizes a volt-free switching output (3A Max).\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e The standard terminal layout is as follows\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\" id=\"p-rc_185e5db4a2452d5b-97\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eL \u0026amp; N:\u003c\/b\u003e \u003cspan class=\"citation-175 citation-end-175\"\u003e230V AC Mains Input (Live \u0026amp; Neutral)\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eA1 \u0026amp; A2:\u003c\/b\u003e Volt-free switch contacts (for the boiler\/underfloor wiring center).\u003c\/p\u003e\n\u003cul data-path-to-node=\"9,1,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,1,0,0\" id=\"p-rc_185e5db4a2452d5b-98\"\u003e\u003cspan class=\"citation-174\"\u003e\u003c\/span\u003e\u003ci data-path-to-node=\"9,1,1,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-174\"\u003eNote for 230V Switched Live systems:\u003c\/span\u003e\u003c\/i\u003e\u003cspan class=\"citation-174\"\u003e If your boiler requires a 230V live signal to turn on (rather than a dry contact), \u003c\/span\u003e\u003cb data-path-to-node=\"9,1,1,0,0\" data-index-in-node=\"120\"\u003e\u003cspan class=\"citation-174\"\u003eyou must add a link wire between L and A1\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-174 citation-end-174\"\u003e.\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-173\"\u003eTerminal \u003c\/span\u003e\u003cb data-path-to-node=\"9,1,1,0,0\" data-index-in-node=\"172\"\u003e\u003cspan class=\"citation-173\"\u003eA2\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-173 citation-end-173\"\u003e then becomes your 230V Switched Live output to the boiler.\u003csup class=\"superscript\" data-turn-source-index=\"8\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\" id=\"p-rc_185e5db4a2452d5b-99\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eRT+ \u0026amp; RT-:\u003c\/b\u003e \u003cspan class=\"citation-172 citation-end-172\"\u003eOptional remote air\/floor sensor connections (such as a thimble sensor for bathroom control).\u003csup class=\"superscript\" data-turn-source-index=\"9\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003cspan class=\"citation-171 citation-end-171\"\u003eThe thermostat automatically disables its internal sensor when a remote sensor is connected.\u003csup class=\"superscript\" data-turn-source-index=\"10\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"11\"\u003e3. Setting the Switching Differential (DIP Switches)\u003c\/h3\u003e\n\u003cp data-path-to-node=\"12\" id=\"p-rc_185e5db4a2452d5b-100\"\u003e\u003cspan class=\"citation-170 citation-end-170\"\u003eThe switching differential determines how far the room temperature must drop below your target before the heating kicks back on.\u003csup class=\"superscript\" data-turn-source-index=\"11\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003cp data-path-to-node=\"13\" id=\"p-rc_185e5db4a2452d5b-101\"\u003eThe DS1 V2 has \u003cb data-path-to-node=\"13\" data-index-in-node=\"15\"\u003etwo small DIP switches\u003c\/b\u003e on the back of the circuit board. \u003cspan class=\"citation-169 citation-end-169\"\u003eYou can set them to \u003csup class=\"superscript\" data-turn-source-index=\"12\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"1^\\circ\\text{C}\" data-index-in-node=\"92\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e1\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mbin mtight\"\u003e∘\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-168 citation-end-168\"\u003e, \u003csup class=\"superscript\" data-turn-source-index=\"13\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"2^\\circ\\text{C}\" data-index-in-node=\"109\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e2\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mbin mtight\"\u003e∘\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-167 citation-end-167\"\u003e, or \u003csup class=\"superscript\" data-turn-source-index=\"14\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"math-inline\" data-math=\"3^\\circ\\text{C}\" data-index-in-node=\"129\"\u003e\u003cspan class=\"katex\"\u003e\u003cspan class=\"katex-html\" aria-hidden=\"true\"\u003e\u003cspan class=\"base\"\u003e\u003cspan class=\"strut\"\u003e\u003c\/span\u003e\u003cspan class=\"mord\"\u003e3\u003cspan class=\"msupsub\"\u003e\u003cspan class=\"vlist-t\"\u003e\u003cspan class=\"vlist-r\"\u003e\u003cspan class=\"vlist\"\u003e\u003cspan class=\"\"\u003e\u003cspan class=\"pstrut\"\u003e\u003c\/span\u003e\u003cspan class=\"sizing reset-size6 size3 mtight\"\u003e\u003cspan class=\"mbin mtight\"\u003e∘\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"mord text\"\u003e\u003cspan class=\"mord\"\u003eC\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"citation-166 citation-end-166\"\u003e depending on how frequently you want your boiler to cycle.\u003csup class=\"superscript\" data-turn-source-index=\"15\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003cdiv class=\"horizontal-scroll-wrapper\"\u003e\n\u003cdiv class=\"table-block-component\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003cdiv class=\"table-block has-export-button new-table-style has-scrollbar is-at-scroll-start\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e","brand":"Heatmiser","offers":[{"title":"Default Title","offer_id":55607427924344,"sku":null,"price":18.99,"currency_code":"GBP","in_stock":true}]},{"product_id":"mitsubishi-pac-th011-e","title":"Mitsubishi - PAC-TH011-E","description":"\u003cdiv class=\"container\"\u003e\n\u003cdiv class=\"markdown markdown-main-panel enable-luminous-fast-follows enable-updated-hr-color stronger tutor-markdown-rendering\" id=\"model-response-message-contentr_1dc519725921a740\" aria-busy=\"false\" aria-live=\"off\" dir=\"ltr\"\u003e\n\u003cp data-path-to-node=\"0\" id=\"p-rc_a19db95020cd9b57-29\"\u003e\u003cspan class=\"citation-29\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003e\u003cspan class=\"citation-29\"\u003eMitsubishi Electric PAC-TH011-E\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-29\"\u003e (often misread as \u003c\/span\u003e\u003ci data-path-to-node=\"0\" data-index-in-node=\"54\"\u003e\u003cspan class=\"citation-29\"\u003ePSC-TH011-E\u003c\/span\u003e\u003c\/i\u003e\u003cspan class=\"citation-29\"\u003e) is a \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"72\"\u003e\u003cspan class=\"citation-29\"\u003etemperature sensor\/thermistor set\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-29\"\u003e designed for Mitsubishi \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"130\"\u003e\u003cspan class=\"citation-29\"\u003eEcodan\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-29 citation-end-29\"\u003e air-to-water heat pump systems.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Overview\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\" id=\"p-rc_a19db95020cd9b57-30\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003ePrimary Function:\u003c\/b\u003e \u003cspan class=\"citation-28 citation-end-28\"\u003eMonitors flow and return water temperatures for heating circuits, buffer\/decoupling tanks, or dual-zone heating setups (Zone 1 \/ Zone 2)\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\" id=\"p-rc_a19db95020cd9b57-31\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eSystem Integration:\u003c\/b\u003e \u003cspan class=\"citation-27 citation-end-27\"\u003eConnects directly into the main control board\/interface (such as FTC5 or FTC6) to send accurate temperature feedback to the heat pump controller.\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\" id=\"p-rc_a19db95020cd9b57-32\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eWhat's Included:\u003c\/b\u003e \u003cspan class=\"citation-26\"\u003eTypically supplied as a pair of thermistor sensors (THW6 \u0026amp; THW7 or THW8 \u0026amp; THW9) attached to \u003c\/span\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"109\"\u003e\u003cspan class=\"citation-26\"\u003e5-meter leads\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-26 citation-end-26\"\u003e for flexible positioning during installation\u003c\/span\u003e\u003c\/p\u003e\n\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eFlow \u0026amp; Return Monitoring:\u003c\/b\u003e Measures water leaving and returning from secondary circuits to maintain balanced delta-T control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eCompatible Controllers (FTC Series)\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe PAC-TH011-E plugs directly into Mitsubishi's \u003cb data-path-to-node=\"3\" data-index-in-node=\"49\"\u003eFlow Temperature Controller (FTC)\u003c\/b\u003e mainboards:\u003c\/p\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\" id=\"p-rc_f74d3b3b359b2553-45\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eFTC4\u003c\/b\u003e \u003cspan class=\"citation-73 citation-end-73\"\u003e(e.g., PAC-IF051 \/ PAC-IF052)\u003csup class=\"superscript\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\" id=\"p-rc_f74d3b3b359b2553-46\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eFTC5\u003c\/b\u003e \u003cspan class=\"citation-72 citation-end-72\"\u003e(e.g., PAC-IF061 \/ PAC-IF062)\u003csup class=\"superscript\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\" id=\"p-rc_f74d3b3b359b2553-47\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eFTC6\u003c\/b\u003e \u003cspan class=\"citation-71 citation-end-71\"\u003e(e.g., PAC-IF071 \/ PAC-IF072)\u003csup class=\"superscript\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\" id=\"p-rc_f74d3b3b359b2553-48\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eFTC7\u003c\/b\u003e \u003cspan class=\"citation-70 citation-end-70\"\u003e(e.g., PAC-IF081 \/ PAC-IF082)\u003csup class=\"superscript\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eCompatible Indoor Units\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\" id=\"p-rc_f74d3b3b359b2553-49\"\u003e\u003cspan class=\"citation-69 citation-end-69\"\u003eIt works seamlessly with Mitsubishi’s Ecodan hydrobox and cylinder units, including:\u003csup class=\"superscript\" data-turn-source-index=\"6\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eHydrobox \/ Packaged Units:\u003c\/b\u003e EHSC, EHSB, EHSE, ERSC, ERSB series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003ePre-Plumbed \u0026amp; Standard Cylinder Units:\u003c\/b\u003e EHST, ERST, EHPT, ERPT series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\" id=\"p-rc_f74d3b3b359b2553-50\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eControl Interfaces \/ Heat Source Controllers:\u003c\/b\u003e \u003cspan class=\"citation-68 citation-end-68\"\u003ePAC-IF series FTC boxes\u003csup class=\"superscript\" data-turn-source-index=\"7\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003col start=\"1\" data-path-to-node=\"6\"\u003e\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55613100425592,"sku":"vme16","price":52.5,"currency_code":"GBP","in_stock":true}]},{"product_id":"mitsubishi-fan-motor-s70e95763","title":"Mitsubishi Fan Motor S70E95763","description":"\u003cp\u003ehe \u003cb\u003eMitsubishi Electric S70E95763\u003c\/b\u003e (also reference \u003cb\u003e312416\u003c\/b\u003e) is an original equipment manufacturer replacement fan motor designed for outdoor heat pump and air conditioning condensing units.\u003c\/p\u003e\n\u003cdiv class=\"attachment-container search-images\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cp\u003eThis motor drives the outdoor unit's fan blade, maintaining steady airflow across the coil to ensure efficient heat transfer in heating and cooling modes. Using an authentic OEM replacement prevents issues with mismatched power specifications, shaft dimensions, mounting alignment, and control logic communication.\u003c\/p\u003e\n\u003ch4\u003eCompatible Models\u003c\/h4\u003e\n\u003cp\u003eThis fan motor is used across a wide range of Mitsubishi Electric commercial and residential outdoor units, including various \u003cb\u003eEcodan\u003c\/b\u003e heat pumps and \u003cb\u003eMr. Slim \/ Power Inverter\u003c\/b\u003e series:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePUHZ Series:\u003c\/b\u003e PUHZ-W60VAA, PUHZ-W85VAA, PUHZ-W85YAA, PUHZ-SW75VAA, PUHZ-SW75YAA\u003c\/p\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePUZ-WM \/ PUD Series:\u003c\/b\u003e PUZ-WM85VAA, PUZ-WM85YAA, PUD-SWM60VAA, PUD-SWM80VAA, PUD-SHWM60VAA, PUD-SHWM80YAA\u003c\/p\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePUZ-ZM Series:\u003c\/b\u003e \u003ccode\u003e\u003c\/code\u003ePUZ-ZM100VKA, PUZ-ZM100YKA, PUZ-ZM125VKA, PUZ-ZM125YKA, PUZ-ZM140VKA, PUZ-ZM140YKA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eReplacement Notes\u003c\/h4\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cb\u003eImportant:\u003c\/b\u003e Always verify the part code printed directly on the label of your existing fan motor before ordering, as outdoor units may vary slightly depending on the exact sub-model revision and production year.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eFailure Symptoms:\u003c\/b\u003e Common indicators that the fan motor needs replacement include error codes related to fan speed fault (such as \u003ccode\u003eP8\u003c\/code\u003e or fan lock errors), visible physical resistance when hand-spinning the blade (power turned off), or unusual bearing grinding\/whining noises during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eInstallation Tip:\u003c\/b\u003e Ensure power to the main isolator is completely disconnected before working inside the electrical compartment. Take care not to bend or damage the plastic fan blades during disassembly, as an unbalanced blade can cause premature bearing wear on the new motor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55619883663736,"sku":"vme17","price":254.38,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/add-a-heat-pump-brighter-green_2b540681-cec6-41d2-b8fe-4ba4785dc85d.png?v=1780741317"},{"product_id":"mitsubishi-fan-motor-s70e95763-copy","title":"Mitsubishi Fan Blade S70E50115","description":"\u003cp\u003e\u003cb\u003eMitsubishi Electric S70E50115\u003c\/b\u003e (also reference \u003cstrong\u003e277920\u003c\/strong\u003e) is an original equipment manufacturer replacement fan blade designed for outdoor heat pump and air conditioning condensing units.\u003c\/p\u003e\n\u003cdiv class=\"attachment-container search-images\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cp\u003eThis motor drives the outdoor unit's fan blade, maintaining steady airflow across the coil to ensure efficient heat transfer in heating and cooling modes.\u003c\/p\u003e\n\u003ch4\u003eCompatible Models\u003c\/h4\u003e\n\u003cp\u003eThis fan blade is used across a wide range of Mitsubishi Electric commercial and residential outdoor units, including various \u003cb\u003eEcodan\u003c\/b\u003e heat pumps and \u003cb\u003eMr. Slim \/ Power Inverter\u003c\/b\u003e series:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eEcodan Heat Pumps (PUD \/ PUHZ Series):\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUD-SWM60VAA.UK \/ PUD-SWM80VAA.UK \/ PUD-SWM100VAA.UK \/ PUD-SWM120YAA.UK\u003c\/p\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUD-SHWM80VAA-UK \/ PUD-SHWM100YAA.UK \/ PUD-SHWM140YAA.UK\u003c\/p\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-SW75VAA \/ PUHZ-SW75YAA \/ PUHZ-SW100YAA \/ PUHZ-SW160YKA \/ PUHZ-SW200YKA\u003c\/p\u003e\n\u003cp\u003e\u003ccode\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-W60VAA.UK \/ PUHZ-W85VAA.UK \/ PUHZ-W112YAA.UK\u003c\/p\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-SHW80VAA \/ PUHZ-SHW112YAA\u003c\/p\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCommercial \u0026amp; Multi-Split Units (PUZ \/ PUHZ Power Inverter):\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\"\u003ePUZ-WM60VAA \/ PUZ-WM85VAA \/ PUZ-WM112VAA \/ PUZ-WM112YAA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\"\u003ePUZ-ZM100VKA \/ PUZ-ZM125VKA \/ PUZ-ZM140VKA \/ PUZ-ZM200YKA \/ PUZ-ZM250YKA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ccode\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\"\u003ePUHZ-ZRP100YKA \/ PUHZ-ZRP125YKA \/ PUHZ-ZRP140YKA \/ PUHZ-ZRP250YKA\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003ch4\u003eReplacement Notes\u003c\/h4\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cb\u003eImportant:\u003c\/b\u003e Always verify the part code printed directly on the label of your existing fan blade before ordering, as outdoor units may vary slightly depending on the exact sub-model revision and production year.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eInstallation Tip:\u003c\/b\u003e Ensure power to the main isolator is completely disconnected before working inside the electrical compartment. Take care not to bend or damage the plastic fan blades during disassembly, as an unbalanced blade can cause premature bearing wear on the motor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55622843269496,"sku":"vme18","price":109.36,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/add-a-heat-pump-brighter-green_2b540681-cec6-41d2-b8fe-4ba4785dc85d.png?v=1780741317"},{"product_id":"mitsubishi-fan-blade-s70e50115-copy","title":"Mitsubishi Fan Blade R01E10115","description":"\u003cp\u003e\u003cb\u003eMitsubishi Electric R01E10115\u003c\/b\u003e (also reference \u003cstrong\u003e225095\u003c\/strong\u003e ) is an original equipment manufacturer replacement fan blade designed for outdoor heat pump and air conditioning condensing units.\u003c\/p\u003e\n\u003cdiv class=\"attachment-container search-images\"\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cp\u003eThis motor drives the outdoor unit's fan blade, maintaining steady airflow across the coil to ensure efficient heat transfer in heating and cooling modes.\u003c\/p\u003e\n\u003ch4\u003eCompatible Models\u003c\/h4\u003e\n\u003cp\u003eThis fan blade is used across a wide range of Mitsubishi Electric commercial and residential outdoor units, including various \u003cb\u003eEcodan\u003c\/b\u003e heat pumps and \u003cb\u003eMr. Slim \/ Power Inverter\u003c\/b\u003e series:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eEcodan Heat Pumps (PUHZ Series):\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-ZRP140VKA , PUHZ-ZRP100YKAR1.SH, PUHZ-RP125YKAR4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-ZRP140YKA.SH, PUHZ-SHW230YKA, PUHZ-RP140YKA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-SHW230YKA2R1, PUHZ-ZRP100YKAR1,\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003ePUHZ-RP200YKA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-RP125YKA, PUHZ-ZRP100YKA, PUHZ-ZRP100VKA, PUHZ-ZRP140YKA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-RP250YKA, PUHZ-RP200YKAR1, PUHZ-ZRP140VKA.SH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-ZRP125YKA.SH,\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003ePUHZ-RP100YKAR4, PUHZ-ZRP100YKA.SH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-RP100VKA, PUHZ-ZRP100VKA.SH,  PUHZ-RP125VKA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-ZRP140YKAR1.SH, PUHZ-RP140VKA, PUHZ-ZRP125YKAR1.SH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-SHW230YKA2R2, PUHZ-SHW230YKA2, PUHZ-ZRP125YKA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-HRP200YKA, PUHZ-ZRP140YKAR1, PUHZ-SHW230YKAR1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"MsoNormal\"\u003ePUHZ-ZRP125YKAR1, PUHZ-ZRP125VKA,\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003ePUHZ-RP100YKA\u003c\/p\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003ch4\u003eReplacement Notes\u003c\/h4\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cb\u003eImportant:\u003c\/b\u003e Always verify the part code printed directly on the label of your existing fan blade before ordering, as outdoor units may vary slightly depending on the exact sub-model revision and production year.\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":55624695021944,"sku":"vme19","price":109.36,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/files\/SAM_0232_839871e4-b929-4840-917f-b0b7f97bc4d2.jpg?v=1786093429"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/0496\/7984\/collections\/mitsubishi-electric-logo.png?v=1750426646","url":"https:\/\/varme-tec.com\/collections\/mitsubishi-heat-pumps.oembed?page=2","provider":"Varmetec Limited","version":"1.0","type":"link"}