Mitsubishi Electric
Mitsubishi - PAC-TH011-E
Mitsubishi - PAC-TH011-E
Couldn't load pickup availability
Description
The Mitsubishi Electric PAC-TH011-E (often misread as PSC-TH011-E) is a temperature sensor/thermistor set designed for Mitsubishi Ecodan air-to-water heat pump systems.
Key Overview
-
Primary Function: Monitors flow and return water temperatures for heating circuits, buffer/decoupling tanks, or dual-zone heating setups (Zone 1 / Zone 2)
-
System Integration: Connects directly into the main control board/interface (such as FTC5 or FTC6) to send accurate temperature feedback to the heat pump controller.
-
What's Included: Typically supplied as a pair of thermistor sensors (THW6 & THW7 or THW8 & THW9) attached to 5-meter leads for flexible positioning during installation
Flow & Return Monitoring: Measures water leaving and returning from secondary circuits to maintain balanced delta-T control.
Compatible Controllers (FTC Series)
The PAC-TH011-E plugs directly into Mitsubishi's Flow Temperature Controller (FTC) mainboards:
-
FTC4 (e.g., PAC-IF051 / PAC-IF052)
-
FTC5 (e.g., PAC-IF061 / PAC-IF062)
-
FTC6 (e.g., PAC-IF071 / PAC-IF072)
-
FTC7 (e.g., PAC-IF081 / PAC-IF082)
Compatible Indoor Units
It works seamlessly with Mitsubishi’s Ecodan hydrobox and cylinder units, including:
-
Hydrobox / Packaged Units: EHSC, EHSB, EHSE, ERSC, ERSB series
-
Pre-Plumbed & Standard Cylinder Units: EHST, ERST, EHPT, ERPT series
-
Control Interfaces / Heat Source Controllers: PAC-IF series FTC boxes